Sandwich Human ELISA Kit GPR173 Immunoassay Test Kit For Accurate Quantitative Detection

Shanghai Korain Biotech Co., Ltd
Contact Now

Sandwich Human ELISA Kit GPR173 Immunoassay Test Kit For Accurate Quantitative Detection

Brand Name : BT Lab

Model Number : Cat.No E6639Hu

Certification : CE, ISO9001:2005, MSDS

Place of Origin : Shanghai, China

MOQ : Negotiation

Price : Negotiation

Supply Ability : Western Union, T/T

Delivery Time : 1-3 business days, bulk order within one week

Packaging Details : Wrapped with ice pack and styrofoam package

Shipping : DHL/FedEX

Lead Time : Within 48 hours

Storage : 2-8°C

Assay Principle : Sandwich

Discount : Available

Sample : serum,plasma,urine,tissue,cell culture supernatan

Contact Now

High Sensitivity and Specificity Human GPR173 Immunoassays Test Kit For Accurate Quantitative Detection

*This product is for research use only, not for use in diagnosis procedures. It’s highly recommend to read this instruction entirely before use.

Intended Use

This sandwich kit is for the accurate quantitative detection of Human Probable G-protein Coupled Receptor 173 (also known as GPR173) in serum, plasma, cell culture supernates, cell lysates, tissue homogenates.

Assay Principle

This ELISA Test Kit is an Enzyme-Linked Immunosorbent Assay (ELISA). The plate has been pre-coated with Human GPR173 antibody. GPR173 present in the sample is added and binds to antibodies coated on the wells. And then biotinylated Human GPR173 Antibody is added and binds to GPR173 in the sample. Then Streptavidin-HRP is added and binds to the Biotinylated GPR173 antibody. After incubation unbound Streptavidin-HRP is washed away during a washing step. Substrate solution is then added and color develops in proportion to the amount of Human GPR173. The reaction is terminated by addition of acidic stop solution and absorbance is measured at 450 nm.

Cat.No E6639Hu

Standard Curve Range: 20ng/L - 6000ng/L

Sensitivity: 11.84ng/L

Size: 96 wells

Reagent Provided

Components Quantity
Standard Solution (6400ng/L) 0.5ml x1
Pre-coated ELISA Plate 12 * 8 well strips x1
Standard Diluent 3ml x1
Streptavidin-HRP 6ml x1
Stop Solution 6ml x1
Substrate Solution A 6ml x1
Substrate Solution B 6ml x1
Wash Buffer Concentrate (25x) 20ml x1
Biotinylated Human GPR173 Antibody 1ml x1
User Instruction 1
Plate Sealer 2 pics
Zipper bag 1 pic

Precautions

  • Prior to use, the ELISA Test Kit and sample should be warmed naturally to room temperature 30 minutes.
  • This instruction must be strictly followed in the experiment.
  • Once the desired number of strips has been removed, immediately reseal the bag to protect the remain from deterioration. Cover all reagents when not in use.
  • Make sure pipetting order and rate of addition from well-to-well when pipetting reagents.
  • Pipette tips and plate sealer in hand should be clean and disposable to avoid cross-contamination.
  • Avoid using the reagents from different batches together.
  • Substrate solution B is sensitive to light, don’t expose substrate solution B to light for a long time.
  • Stop solution contains acid. Please wear eye, hand and skin protection when using this material. Avoid contact of skin or mucous membranes with kit reagent.
  • The ELISA Test Kit should not be used beyond the expiration date.

Reagent Preparation

All reagents should be brought to room temperature before use.

Standard Reconstitute the 120μl of the standard (6400ng/L) with 120μl of standard diluent to generate a 3200ng/L standard stock solution. Allow the standard to sit for 15 mins with gentle agitation prior to making dilutions. Prepare duplicate standard points by serially diluting the standard stock solution (3200ng/L) 1:2 with standard diluent to produce 1600ng/L, 800ng/L, 400ng/L and 200ng/L solutions. Standard diluent serves as the zero standard(0 ng/L). Any remaining solution should be frozen at -20°C and used within one month. Dilution of standard solutions suggested are as follows:

3200ng/L Standard No.5 120μl Original Standard + 120μl Standard Diluent
1600ng/L Standard No.4 120μl Standard No.5 + 120μl Standard Diluent
800ng/L Standard No.3 120μl Standard No.4 + 120μl Standard Diluent
400ng/L Standard No.2 120μl Standard No.3 + 120μl Standard Diluent
200ng/L Standard No.1 120μl Standard No.2 + 120μl Standard Diluent

Standard Concentration Standard No.5 Standard No.4 Standard No.3 Standard No.2 Standard No.1
6400ng/L 3200ng/L 1600ng/L 800ng/L 400ng/L 200ng/L

Wash Buffer Dilute 20ml of Wash Buffer Concentrate 25x into deionized or distilled water to yield 500 ml of 1x Wash Buffer. If crystals have formed in the concentrate, mix gently until the crystals have completely dissolved.

Summary

1. Prepare all reagents, samples and standards.

2. Add sample and ELISA reagent into each well. Incubate for 1 hour at 37°C.

3. Wash the plate 5 times.

4. Add substrate solution A and B. Incubate for 10 minutes at 37°C.

5. Add stop solution and color develops.

6. Read the OD value within 10 minutes.

Calculation of Result

Construct a standard curve by plotting the average OD for each standard on the vertical (Y) axis against the concentration on the horizontal (X) axis and draw a best fit curve through the points on the graph. These calculations can be best performed with computer-based curve-fitting software and the best fit line can be determined by regression analysis.


Product Tags:

enzyme immunoassay kit

      

enzyme assay kits

      
China Sandwich Human ELISA Kit GPR173 Immunoassay Test Kit For Accurate Quantitative Detection wholesale

Sandwich Human ELISA Kit GPR173 Immunoassay Test Kit For Accurate Quantitative Detection Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Shanghai Korain Biotech Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)